ABB has a wide portfolio of low voltage switches. They are
suitable for diverse applications, in motor control centers,
in switch boards and as main switches in various equipments
and machines. From single to 8 poles and combination
switches for change-over, automatic transfer, bypass,
reversing etc.
Switch disconnectors 16 鈥?4000 A
The switch disconnector is largely used as the main switch
in low voltage switchgears for distribution of power,
starting and stopping motors and isolating loads during
maintenance.
The range from 16 to 125 Amps are either base plate or door
mounted by snap-on or screw fitting front operated 3, 4, 6
and 8-pole are available as standard.
From 160 to 4000 Amps the switch disconnectors, also called
load break switches, are designed as pole modules and
they are available as 1, 2, 3 and 4-pole versions, front or side
operated.
Switch disconnector fuses 16 鈥?1250A
The switch disconnector fuse is used as the main switch
in low voltage switchgears in industry for distributing power
and protecting motors, cables and other devices against
short circuits and over loads.
The switch disconnector fuses are available for all types of
fuse links, DIN, BS, NFC, UL, CSA.
The range includes single pole to four pole versions,
front-or side-operated. The pole module design enables
location of the operating mechanism in any position
together with the direction of the terminals giving flexibility
to installation in different types of cubicle designs.
Change-over and transfer switches 16 鈥?3200 A
ABB鈥檚 change-over and transfer switches are designed to
transfer loads from one power source to another in a wide
variety of applications.
The range includes switches from 16 to 3200 Amperes, which
can be operated manually, remotely by using a motor or
automatically.
ABB鈥檚 change-over and transfer switches are tested
according to IEC 60947-6-1 and IEC 60947-3 standards.
The switches have ratings in AC31 and AC33 utilization
categories, up to 415 V. In motorized switches, the motor
operators have a wide voltage operation range.
Enclosed switches 16 鈥?1600 A
The ABB enclosed switches are suitable for power
distribution in factories and buildings, as local motor
isolators and as main switches. Each incoming supply shall
be provided with a hand operated main switch-disconnector
according to the Machine Directive EN 60204 and isolate
reliably the electrical equipment from the supply.
ABB enclosed switches are designed and tested to meet
these requirements and complies with IEC 60 947-3.
The enclosed switches are easy to install and safe to use
in industrial, public and residential environments. The
indication of the handle is always reliable and lockable in the
OFF-position with a standard padlock. ABB鈥檚 long experience
in switch disconnects guarantees a long and safe use.
All units are applicable for AC voltage, and the 1-pole and
2-pole range are also rated for DC voltage.
In addition to be used as single apparatus, the 3-pole
range from size 00 to size 3 (160A - 630A) are also
designed to be used in distribution systems by use
of a busbar adapter for easy installation. The Busbar
adapters are available for 40 mm, and 60 mm distance
in-between centre of the phases for each busbar systems. The whole EasyLine range got a sturdy, uniform
design that is operator friendly and safe with IP 30
from front in closed position and IP 20 in open position.
EasyLine Fuse Switch Disconnectors are developed and
type tested according to IEC60947-3 and based on a
long history, going back to 1958 when we successfully
introduced the manually dependent operated LHB.
Rated Short-Circuit Breaking Current: 40kA
Rated Short-Time Withstand Current: 40kA
Duration Of Short-Circuit: 3s
Short-Circuit Making Current: 100kA
Rated Operation Sequence: O-0.3s-CO-15s-CO
Features
l All the XLP cable terminals can be delivered with
integrated bolts for cable lugs or with integrated
bridge clamps (BC) for easy direct cable connection
l Typetested according to EN60947-3
l Easy to recycle/EN14001 standards
l Quick-make operation device
l Integrated IP20 cable termination
l IP30 degree of protection from the front
l Replacement compatible to similar types in the market
l Voltage measuring from the front
l V-0 plastic materials
Advantages
l Easy to install
l Easy to operate
l Sturdy design
l High personal safety
l Wide range of cable terminals and snap-on accessories
l Compact, add-on Electronic Fuse Monitoring (EFM)
l Busbar adapters
Applications
l UPS: Uninterruptible Power Supply, used for the power supply
for computer/servers, storage devices, communication
network systems, industry control systems, etc.
l Telecom power supplies
l General protection in smaller distribution panels using
1-pole or 2-pole configurations AC or DC
Features
l Available as 160A, 250A, 400A, 630A, 800 and 1250A
types in combination with NH/DIN HRC Fuse Links
acc. to EN/IEC 60269
l Type tested in accordance to EN/IEC 60947-3
l 1 - pole and 3 - pole variants
l For vertical and horizontal installations
l Designed for 185 mm busbar distance
l IP30 degree of protection from the front
鈥?Padlocking in open and closed position at the
3 - pole version
鈥?Padlocking in closed position at the 1 - pole version
l Park position with possible padlocking at the
1 - pole type
l Sealing solutions
l Wide range of accessories and cable terminal
connections
l Compatible dimensions to equivalent products
in the market
Advantages
l High level of personal safety by:
鈥?Safe and reliable operation ON/OFF
鈥?Safe and simple replacement of the NH fuse links
l Universal terminal bolts offering standing bolt or
fixed nut for high flexibility of cable connections
l Variants with integrated V-clamps
l Available in two alternative depths (ZLBM/ZHBM),
L-version (ZLBM) will save space in Cable Distribution
Cabinets by offering reduced depth
l Easy installation of current transformers in the
H-version (ZHBM)
l Variants with non corrosive steel materials
(stainless steel)
l Designed for intelligent communication to support
a high level of stability in the power distribution
network
Applications
l Cable Distribution Cabinets (CDC)
l Low voltage distribution in compact secondary
substations (CSS)
l Distribution boards for industry, housing and
office buildings
l Installations
Extended Product Type:OS400D02P
Product ID:1SCA022811R2740
EAN:6417019273587
Catalog Description:OS400D02P SWITCH FUSE
Long Description:Switch Fuses,Front Operated,2-pole,02 (Left Side),DIN,0,1,2,Handle and shaft included,
Minimum Order Quantity:1 piece
Customs Tariff Number:85365080
Country of Origin:Finland (FI)
Popular Downloads
Data Sheet, Technical Information:1SCC311013C0201
Instructions and Manuals:1SCC311015M0215
Dimensions
Product Net Width:191 mm
Product Net Height:230 mm
Product Net Depth / Length:193 mm
Product Net Weight:4.79 kg
10.56 lb
Technical
Rated Operational Current AC-21A (Ie):(500 V) 400 A
(690 V) 400 A
Rated Operational Current AC-22A (Ie):(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
Rated Operational Current AC-23A (Ie):(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
Rated Operational Power AC-23A (Pe):(220 ... 240 V) 132 kW
(400 V) 220 kW
(415 V) 230 kW
(500 V) 280 kW
(690 V) 400 kW
Conventional Free-air Thermal Current (Ith):q = 40 掳C 400 A
Conventional Thermal Current (Ithe):Fully Enclosed 400 A
Rated Impulse Withstand Voltage (Uimp):12 kV
Rated Insulation Voltage (Ui):1000 V
Rated Operational Voltage:Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw):for 1 s 14 kiloampere rms
Rated Conditional Short-Circuit Current (Inc):(690 V) 80 kA
Power Loss:at Rated Operating Conditions per Pole 45 W
Pollution Degree:3
Handle Type:Pistol handle and shaft included
Switches Operating Mechanism:02 (Left Side)
Position of Line Terminals:Top In - Bottom Out, Bottom In - Top Out
Fuse Size:0,1,2
Fuse System:DIN
Operating Mode:Front Operated
Standards:IEC 60947-3
Mounting Type:Base mounting
Number of Poles:2
Terminal Type:Lug terminals
Terminal Width:25 mm
Tightening Torque:30 ... 44 N路m
Fuse Type:DIN
Safety for personnel 鈥?reliable position indication
l Padlocking in the OFF-position with one, three or six
(with the shackle L6) padlocks against unintentional
start-up The handle cannot be padlocked in the OFF_x005 FSTX position if one of the contacts is not in the
OFF position
l The cover cannot be removed if the handle is
padlocked
l Door interlock in the ON-position
l Arc proof, short circuit durability function: Expander
washers in aluminium enclosures with Ie > 160 A and
door locking release in large metal sheet enclosures
type MSC
l Door interlock defeatable with rectangular and pistol
type handles