Rib cooled motors, type HXR 560 High efficiency and reliability HXR cast iron motors offer high performance for all applications.
HXR rib cooled motors have a rugged cast iron frame. They are totally enclosed fan cooled motors with IC411 cooling and IP55 protection as standard. The motors are also available with IC416 cooling and optional IP66 protection. HXR motors cover the output range up to 2,250 kW, and they are available in shaft height 560. The motors can be mounted horizontally or vertically. ABB HXR 355LF6 ABB HXR 400LD6 ABB HXR 400LF6 ABB HXR 400LH6 ABB HXR 400LK6 ABB HXR 450LF6 ABB HXR 450LH6 ABB HXR 450LK6 ABB HXR 450LM6 ABB HXR 500LG6 ABB HXR 500LJ6 ABB HXR 500LN6 ABB HXR 500LQ6 ABB HXR 500LS6 ABB HXR 560LN6 ABB HXR 560LR6 ABB HXR 560LU6 HXR 400LB8 360 HXR 400LC8 361 HXR 400LE8 362 HXR 400LF8 363 HXR 400LH8 364 HXR 400LJ8 365 HXR 450LD8 366 HXR 450LE8 367 HXR 450LG8 368 HXR 450LH8 369 HXR 450LL8 370 HXR 500LF8 371 HXR 500LH8 372 HXR 500LK8 373 HXR 500LN8 374 HXR 500LP8 375 HXR 500LR8 376 HXR 560LN8 634 HXR 560LR8 635 HXR 560LU8 636 HXR 400LC10 455 HXR 400LD10 456 HXR 400LE10 457 HXR 400LF10 458 HXR 400LH10 459 HXR 400LK10 460 HXR 450LG10 461 HXR 450LJ10 462 HXR 450LK10 463 HXR 450LM10 464 HXR 500LH10 465 HXR 500LK10 466 HXR 500LM10 467 HXR 500LN10 468 HXR 500LP10 469 HXR 500LR10 470 HXR 560LN10 637 HXR 560LQ10 638 HXR 560LS10 639 HXR 560LU10 640 HXR 400LD12 541 HXR 400LE12 542 HXR 400LG12 543 HXR 400LH12 544 HXR 400LK12 545 HXR 450LH12 546 HXR 450LJ12 547 HXR 450LL12 548 HXR 450LM12 549 HXR 500LJ12 550 HXR 500LL12 551 HXR 500LN12 552 HXR 500LQ12 553 HXR 500LR12 554 HXR 500LS12 555 HXR 560LM12 641 HXR 560LQ12 642 HXR 560LS12 643 HXR 560LU12 644 HXR 355LB2 8663 HXR 355LB2 8664 HXR 355LB2 8665 HXR 355LB2 8666 HXR 355LC2 8667 HXR 355LD2 53 HXR 400LD4 8677 HXR 400LD4 163 HXR 400LE4 164 HXR 400LG4 165 HXR 450LE4 166 HXR 450LG4 167 HXR 450LJ4 168 HXR 500LF4 170 HXR 500LG4 171 HXR 500LJ4 172 HXR 500LP4 173 HXR 500LR4 174 HXR 560LM4 645 HXR 560LR4 646 HXR 560LT4 647 HXR 355LC6 8685 HXR 355LC6 8686 HXR 355LD6 8687 HXR 355LD6 8688 HXR 355LD6 8689 HXR 355LE6 271 HXR 400LC6 273 HXR 400LC6 274 HXR 400LD6 275 HXR 400LF6 276 HXR 400LJ6 277 HXR 450LD6 278 HXR 450LF6 279 HXR 450LH6 280 HXR 450LK6 281 HXR 500LH6 283 HXR 500LJ6 284 HXR 500LK6 285 HXR 500LN6 286 HXR 500LR6 287 HXR 560LM6 648 HXR 560LR6 649 HXR 560LU6 650 HXR 400LC8 377 HXR 400LD8 378 HXR 400LE8 379 224 HXR 450LD10 250 HXR 450LE10 280 HXR 450LF10 315 HXR 450LG10 355 HXR 450LJ10 400 HXR 450LK10 450 HXR 450LM10 500 HXR 500LJ10 560 HXR 500LL10 630 HXR 500LM10 710 HXR 500LP10 800 HXR 500LQ10 900 HXR 500LS10 1000 HXR 560LN10 1120 HXR 560LR10 1250 HXR 560LU10 HXR 400LG12 8698 HXR 450LF12 8699 HXR 400LJ12 558 For HXR motors this catalog shows the technical data at 50 Hz only, but the motors are operating at both 50 Hz and 60 Hz, with synchronous speed from 500 to 3600 rpm. Standard combinations IC411 / IP55 HXR motors have an external shaft mounted fan that uses the surrounding air for cooling. The motors are protected against dust and water jets. The operating principle of these motors is shown in diagram 27 below. Electric Motors manufacturer & provide ABB LV Modular HXR HV Cast ... HXR 400LC4 VSD10002 M2QA 80 M6B 3GQA 083 302-•A HXR 400LD4 VSD10003 IC416 / IP55 HXR motors are available with IC416 cooling. An additional motor drives the cooling fan to produce the cooling required for low speed applications, especially in cases where the motor is fed via a variable speed drive. Protection rating IP55 • Protection against dust: as in other dust- protected motors, some dust can enter but not in sufficient quantities to interfere with the motor’s operation. • Protection against water jets: water projected by a nozzle against the motor from any direction has no harmful effect. Protection rating IP66 HXR motors are available with protection ratings up to IP66. • Protection against dust: the enclosure is completely dust tight. • Protection against water jets: water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction has no harmful effect. HXR 400LF8 380 HXR 400LH8 381 HXR 400LJ8 382 HXR 450LD8 383 HXR 450LF8 384 HXR 450LG8 385 HXR 450LK8 386 HXR 450LM8 387 HXR 450LN8 388 HXR 500LJ8 389 HXR 500LK8 390 HXR 500LL8 391 HXR 500LP8 392 HXR 500LS8 393 HXR 560LM8 651 HXR 560LQ8 652 HXR 560LU8 653 Cooling method (IC411) • Frame surface cooled: The primary coolant is circulated in a closed circuit in the motor and gives its heat through the external surface of the motor (in addition to the heat transfer via the stator core and other heat conducting parts) to the final coolant which is the surrounding medium. The surface may be plain or ribbed, with or without an outer shell to improve the heat transfer. HXR 400LC2 8668 HXR 400LC2 55 HXR 400LD2 56 HXR 400LF2 57 HXR 400LG2 58 HXR 450LF2 59 HXR 450LH2 60 HXR 450LK2 61 HXR 500LG2 62 HXR 500LH2 63 HXR 500LL2 64 HXR 500LN2 65 HXR 500LQ2 66 HXR 560LM2 707 HXR 560LN2 708 HXR 560LS2 709 HXR 355LA4 8671 HXR 355LA4 8672 HXR 355LA4 8673 HXR 355LC4 8674 HXR 355LC4 8675 HXR 355LC4 159 HXR 355LE4 160 HXR 400LC4 8676 • Self circulation: The coolant is moved dependent on the rotational speed of the main motor either by action of the rotor alone or by means of a component designed for this purpose and mounted directly on the rotor of the main motor, or by a fan or pump unit mechanically driven by the rotor or the main motor.Type | HXR |
---|---|
Voltage Class | 6000 V |
Feature | Rib cooled motors |
Motor Rotor Type | 3-Phase squirrel cage motor |
Enclosure | Totally Enclosed Fan Cooled (TEFC) |
IE Class | IE2 |
Motor Power (KW) | 1000 KW |
Number of Poles | 10 |
IP Rating | IP55 |
Mounting Position | IM B3 |
Frame Type | IEC |
Frame Size | 560LQ |
Housing Material | Cast Iron |
Insulation Class | F |
Catalogue Download | ABB High voltage motor catalogue pdf |
Brand | ABB |